Generac PSTS Transfer Switch Bypass Isolation

Generac PSTS Transfer Switch – Bypass Isolation

Duty: ByPass Open
Rating: 400A

Quantity: 2

Call For Pricing

Specifications

  • Contactor-Based Design
  • DUAL DRAWOUT BREAKER POSITION
  • VOLTAGE: 277/480 VAC 3PHASE
  • 3 POLE SWITCH
  • NEMA 1 ENCLOSURE
  • CONTROLLER: ATC-300+ CONTROLLER
  • 48F-MODBUS COMMUNICATION
  • ANNUNCIATOR: NONE
  • CSA C22.2 CERTIFIED
  • CUL LISTED
  • UL1008 LISTED
  • FIVE YEAR EXTENDED WARRANTY
  • OEM – Generac

Download Spec Sheet

Call For Pricing

Generac PSTS Transfer Switch Bypass Isolation

Generac PSTS Transfer Switch – Bypass Isolation

Duty: ByPass Open
Rating: 200A

Quantity: 1

Call For Pricing

Specifications

  • Contactor-Based Design
  • DUAL DRAWOUT BREAKER POSITION
  • VOLTAGE: 277/480 VAC 3PHASE
  • 3 POLE SWITCH
  • NEMA 1 ENCLOSURE
  • CONTROLLER: ATC-300+ CONTROLLER
  • 48F-MODBUS COMMUNICATION
  • ANNUNCIATOR: NONE
  • CSA C22.2 CERTIFIED
  • CUL LISTED
  • UL1008 LISTED
  • FIVE YEAR EXTENDED WARRANTY
  • OEM – Generac

Download Spec Sheet

Call For Pricing

Generac Diesel Generator 500kW MPS 

500KW MPS – 15.2L Expansion
Voltage: 277/480 3 phase

Call For Pricing

Specifications

  • MPS – Parallel Unit
  • FREQUENCY:  60 Hz
  • UL2200
  • Permanent Magnet Excitation
  • EPA Certified
  • SCAQMD
  • ENCLOSURE: L2A Enclosure – Steel
  • Color: Industrial Grey
  • ALTERNATOR: 500 KW
  • 225AH, 1155CCA, Inst
  • 10 Amp Battery Charger
  • Block heater 3000 watt, 208-volt
  • MLCB: 80% Thermal – Magnetic
  • Emergency stop: – Remote E-Stop – Break Glass
  • 120V GFCI and 240V Outlet
  • Std set of 3 Manuals
  • WARRANTY: STANDARD – 1YR P/L/T, 2 YR P
  • Derate Altitude Percent – 3 %
  • Derate Altitude – 3000 Foot
  • Derate Altitude Step – 1000 Foot
  • Derate Step Temperature F – 5 °F
  • Derate Temperature F Percent – 1.7 %
  • Derate Start Temperature F – 104 °F
  • Power Manager Parallel Controller
  • Standby Duty

Download Spec Sheet

Call For Pricing

Generac Industrial 500kW Natural Gas MPS

Generac Natural Gas Generator 500kW MPS 

500KW MPS – 25.8L
Voltage: 277/480 3 phase

Quantity: 2

Call For Pricing

 

Specifications

  • Standby with Demand Response
  • FREQUENCY: 60 Hz
  • UL2200
  • Permanent Magnet Excitation
  • EPA Non Emergency
  • ENCLOSURE: STD Enclosure – Steel
  • ENCLOSURE Color: – Industrial Grey
  • Upsized alternator
  • Alternator Upsize Code – K0832124Y23
  • 225AH, 1155CCA, Inst
  • 10 Amp Battery Charger
  • Block heater 2500W 240V
  • MLCB: 80% Thermal – Magnetic
  • Air Filter Restriction Ind
  • Emergency stop: – Remote E-Stop – Break Glass
  • AC/DC Led Light Kit
  • 120V GFCI and 240V Outlet
  • Alternator Strip Heater
  • CB Aux Contact to Panel Alrm
  • Flex Fuel Line
  • Oil Temp Sender
  • REACTIVE (0.8) PF TESTING: – 1 hour extended test at 0.8 pf
  • Std set of 3 Manuals
  • EXTENDED – 5 YR P/L/T
  • MPS Controllers – PZ Permissive/Load Shed-NEMA3R
  • Derate Altitude Percent – 2.1 %
  • Derate Altitude – 3500 Foot
  • Derate Altitude Step – 1000 Foot
  • Derate Step Temperature F – 5 °F
  • Derate Temperature F Percent – 2.5 %
  • Derate Start Temperature F – 104 °F
  • CONTROL PANEL: – Power Zone
  • MPS Breaker Material – CB 0800A 3P 600V E MD T 2A
  • Customer or Internal Model No – MG500
  • Product hierarchy – 200,080,000,100,000,003.00