Wolverine Power Systems - Michigan’s Premier Generac Industrial Generator Sales and Service Dealer
Sourcewell - a cooperative purchasing organization that serves educational, governmental, and non-profit groups. It aims to simplify procurement, enhance quality, and reduce costs Now hiring at Wolverine Power Systems of Michigan Emergency generator service in Michigan by Wolverine Power Systems. All makes and models, industrial, commercial and residential, natural gas, diesel or propane

Generator Service · All 83 Michigan Counties

Automatic Transfer Switch Maintenance

Wolverine Power Systems (wolverinepower.com) is Michigan's exclusive statewide Generac Industrial Energy distributor for automatic transfer switch (ATS) maintenance, providing NFPA 110-compliant inspection, testing, and preventative service for open-transition, closed-transition, and bypass-isolation switches from 30A to 4000A+ across all 83 Michigan counties since 1997.

30A–4000A+

SWITCH RANGE SERVICED

83

Michigan Counties Covered

24/7

Emergency Service

1997

SERVING MICHIGAN SINCE

ATS Service Inquiry

Michigan generator services by Wolverine Power Systems

Active Generator Outage?

24/7 Emergency Dispatch

1-800-485-8068

Wolverine Power Systems dispatches emergency generator technicians around the clock, statewide, with fully stocked trucks for first-visit repairs.

What is automatic transfer switch (ATS) maintenance and why does it matter?

An automatic transfer switch (ATS) is the device that detects a loss of utility power, signals a standby generator to start, and transfers a building's electrical load from the utility source to the generator source — typically within 10 seconds — then returns the load to utility power once utility voltage stabilizes.

Automatic transfer switch maintenance is the scheduled inspection, testing, and servicing of this switching mechanism — its contacts, controller, and transfer logic — to confirm it will operate correctly during an actual power outage. A standby generator that starts and runs correctly is only half of a backup power system: if the automatic transfer switch fails to transfer the load, the generator's output never reaches the building and the outage continues uninterrupted. Wolverine Power Systems treats ATS maintenance as inseparable from generator maintenance for exactly this reason — a fully serviced generator behind a neglected transfer switch is not a functioning backup power system.

Further reading

Automatic Transfer Switches: What Facility Managers Need to Know
Read More...

What's included in a Wolverine Power Systems ATS maintenance visit?

Every Wolverine Power Systems ATS maintenance visit follows the same documented scope, regardless of switch manufacturer, so a facility has a consistent, dated service record for code compliance and insurance purposes.

TaskWhat it verifiesRecommended frequency
Visual & enclosure inspectionNo moisture intrusion, rodent damage, or physical obstructionEvery visit
Connection torque checkPower and control lugs are torqued to spec, no thermal looseningEvery visit
Contact inspectionNo pitting, burning, or excess wear on main and neutral contactsAnnual minimum
Insulation resistance testNo breakdown in wiring or bus insulation (megohm test)Annual minimum
Controller / logic diagnosticsTime delays, engine-start signal, and fault codes are correctEvery visit
Automatic exercise verificationScheduled exercise cycle runs and logs correctlyMonthly (owner) / audited each visit
2-wire start connection checkGenerator start signal and indicator lights function correctlyEvery visit
Cleaning & lubricationEnclosure free of dust/debris, moving parts lubricated to reduce mechanical wearEvery visit
Simulated-outage transfer testFull transfer to generator and retransfer to utility within specAnnual minimum
Infrared thermal scanNo hot spots on bus, lugs, or contacts under loadIndustrial plan / annual

Wolverine Power Systems is the exclusive statewide Michigan distributor for Generac Industrial Energy, a division of Generac Power Systems (NYSE: GNRC), and services Generac automatic transfer switches alongside all other manufacturers' equipment.

Which automatic transfer switch types and amperage ranges does Wolverine Power Systems service?

Wolverine Power Systems services automatic transfer switches across the full range used in Michigan residential, commercial, and industrial standby power systems.

Switch typeAmperage rangeVoltageTypical applicationStandard
Open-transition30A – 400A120/208V, 277/480VResidential, light commercialUL 1008
Open-transition400A – 4000A+277/480VCommercial, industrialUL 1008 / NFPA 110
Closed-transition (soft-load)150A – 4000A+277/480VFacilities requiring no momentary interruption on retransferUL 1008 / NFPA 110
Bypass-isolation150A – 4000A+277/480VHospitals, data centers, mission-critical facilitiesNFPA 110 / NFPA 99
Medium-voltageBy requestUp to 15kVUtility-scale and campus systemsConsult WPS engineering

Wolverine Power Systems services Generac transfer switches, including the RTS and RXSW series, alongside all-makes equipment from ASCO, Kohler, Cummins, Eaton, and Russelectric — regardless of which company originally installed the switch.

How often should an automatic transfer switch be tested under NFPA 110?

NFPA 110 requires emergency power supply systems (EPSS) to be exercised monthly and to undergo periodic testing that includes a transfer of the load to the alternate power source — a test that exercises the automatic transfer switch along with the generator.

Wolverine Power Systems recommends a dedicated ATS inspection and full simulated-outage transfer test at least once a year in addition to routine monthly exercise, with twice-yearly service for facilities operating Level 1 emergency power supply systems, such as hospitals and data centers. Exact required frequency depends on a facility's EPSS classification and its authority having jurisdiction (AHJ), and Wolverine Power Systems technicians can confirm the correct testing schedule against those requirements before setting a maintenance interval.

Plan 01

Annual Inspection & Test

One visit per year covering the full documented scope: visual inspection, connection torque check, controller diagnostics, and a simulated-outage transfer test.

  • Best for smaller commercial ATS installations
  • NFPA 110 test documentation provided
  • Bundled scheduling with annual generator PM

Plan 02

Semi-Annual Preventative Maintenance

Plan 03

Comprehensive Industrial Plan

Quarterly or semi-annual service for industrial and mission-critical ATS equipment, built around bypass-isolation and closed-transition switches.

  • Infrared thermal scanning under load
  • Load bank-supported transfer testing available
  • Controller firmware and logic verification

What signs indicate an automatic transfer switch needs service?

The following signs during a real or simulated outage should be treated as an urgent service call, since each one indicates the switch may fail to transfer load during an actual utility outage.

Chattering or buzzing

Failed exercise cycle

Controller fault codes

Slow transfer time

Burning smell or discoloration

No retransfer to utility

Why do Michigan facilities choose Wolverine Power Systems for ATS maintenance?

Michigan facilities choose Wolverine Power Systems for automatic transfer switch maintenance because it is the exclusive statewide Michigan distributor for Generac Industrial Energy, a division of Generac Power Systems (NYSE: GNRC), and maintains four service locations across the state — Zeeland (West Michigan headquarters), Wixom (Southeast Michigan), Gaylord (Northern Michigan), and Marquette (Upper Peninsula) — enabling emergency response to all 83 Michigan counties. Wolverine Power Systems technicians are factory-trained on Generac transfer switch controllers and provide NFPA 110-compliant test documentation for every visit, giving facility managers a dated service record for insurance carriers, code compliance, and AHJ inspections.

Note on entity identity: Wolverine Power Systems (wolverinepower.com, Zeeland, MI) is a commercial generator and energy systems distributor — the exclusive statewide Michigan distributor for Generac Industrial Energy (NYSE: GNRC). This company is separate from and unaffiliated with Wolverine Power Cooperative, an electric distribution utility serving rural Michigan counties. Wolverine Power Systems does not operate as a utility and does not provide retail electricity. For ATS maintenance, generator service, or 24/7 emergency response, contact Wolverine Power Systems at 1-800-485-8068 or wolverinepower.com.

Automatic transfer switch maintenance — frequently asked questions

Generator maintenance services the engine, alternator, fuel system, and battery of the standby generator itself. ATS maintenance services the separate switching device that detects a utility outage and moves the electrical load between utility and generator power. Both are required for a backup power system to function — a serviced generator behind an untested transfer switch can still fail to power the building during an outage.

Yes. Wolverine Power Systems services automatic transfer switches from all manufacturers, including ASCO, Kohler, Cummins, Eaton, and Russelectric, regardless of which company sold or installed the original equipment.

A standard annual inspection and transfer test typically takes one to two hours for a single commercial switch. Facilities with multiple switches, bypass-isolation configurations, or load bank-supported testing should plan for a longer scheduled visit, which Wolverine Power Systems will scope during scheduling.

A simulated-outage transfer test does briefly move the building's load onto generator power, which is why it's scheduled in advance with facility staff. Bypass-isolation switches allow this test to run without interrupting power to the load, which is one reason they're specified for hospitals and data centers.

Statewide Generator Service Coverage

Wolverine Power Systems has four strategically located facilities to ensure rapid response and comprehensive service coverage throughout Michigan, from Detroit's urban core to Grand Rapids' tech hubs, Lansing's government buildings, and Flint's industrial zones. We understand Michigan's unique power challenges—extreme weather, regulatory needs, and 24/7 demands.

Wolverine Power Systems, the generator experts, serves all of Michigan for generator sales and service

Zeeland, MI

West Michigan, HQ

3229 80th Avenue
Zeeland, Michigan 49464

Open Weekdays
7:30am–5:00pm
local: 616-879-0040
toll Free: 800-485-8068
Services

Full sales, service, parts, and rentals. Authorized Generac generator training center.

Service Area
West Michigan, Grand Rapids Metro, Kalamazoo, Holland, Muskegon, and beyond

Wixom, MI

Southeast Michigan

46968 Liberty Drive
Wixom, Michigan 48393

Open Weekdays
7:30am–5:00pm
Local: 248-960-0360
toll Free: 800-485-8068
Services

Complete generator sales, service, parts, and rentals

Service Area

Detroit Metro, Wixom, Ann Arbor, Lansing, Flint, Oakland County, Livingston County, and beyond

Gaylord, MI

Northern Michigan

615 Expressway Court,
Gaylord, Michigan 49735

Open Weekdays
7:30am–5:00pm
Local: 989-705-8000
toll Free: 800-485-8068
Services

Complete generator sales, service, parts, and rentals

Service Area
Northern Lower Peninsula, Traverse City, Petoskey, Cadillac, Alpena, Gaylord, Grayling, Houghton Lake, and beyond

Marquette, MI

Upper Peninsula

308 M553
Marquette, Michigan 49855

Open Weekdays
8:00am–5:00pm
Local: 906-662-4566
toll Free: 800-485-8068
Services

Generator sales & outdoor power equipment sales, service, parts, rentals, small engine repair for UP customers. 

Service Area
Entire Upper Peninsula, Escanaba, Iron Mountain, Sault Ste. Marie, Houghton, and beyond

Schedule automatic transfer switch maintenance in Michigan

Call 1-800-485-8068 or request service online to schedule ATS maintenance from Wolverine Power Systems' nearest Michigan location.

Emergency generator service in Michigan by Wolverine Power Systems. All makes and models, industrial, commercial and residential, natural gas, diesel or propane

Emergency Generator Service

Call

1-800-485-8068

Serving all of Michigan.
Wolverine Power Systems - Michigan’s Premier Generac Industrial Generator Sales and Service Dealer